Power, heat and cooling where you need it.

Cogeneration (electricity + heat) or trigeneration (electricity + heat + cooling) with microturbines in parallel, grid-connected or islanded.

Data center rack room

Data centers and AI

The ID units bring together microturbines, a battery, a dry cooler and an absorption chiller in a 40 ft HC container, ready for AI racks wherever there is gas and fiber.

  • No grid connection queue; deployment in a container
  • N+1 on the turbines and a battery for load transients
  • Scale in blocks as inference demand grows

Manufacturer specifications at ISO conditions, PCI (LHV). Performance varies with operating conditions.

Meet the ID units for data centers
Talk to a specialist
Industrial plant

Industrial generation

Continuous power with heat recovery for steam, hot water, drying or process cooling.

  • Reduced contracted demand
  • Process heat from the exhaust at ~190 °C
  • 24/7 operation with minimal maintenance

Manufacturer specifications at ISO conditions, PCI (LHV). Performance varies with operating conditions.

Talk to a specialist
Supermarket, illustrative imageIllustrative image

Commerce and retail

Supermarkets and stores with refrigeration and air-conditioning loads all day long.

  • Generation at the point of use
  • Absorption cooling from exhaust heat
  • Backup for the cold chain
Talk to a specialist
Shopping center, illustrative imageIllustrative image

Shopping centers

Trigeneration for high air-conditioning loads, with modular units installed on the roof or in a technical area.

  • Lower cost during peak hours
  • Air conditioning with recovered heat
  • Modular redundancy
Talk to a specialist
Wastewater treatment plant, illustrative imageIllustrative image

Wastewater treatment

Biogas from the digesters becomes electricity for the plant itself, and exhaust heat warms the digesters.

  • Self-consumption of energy
  • Digester heating
  • Less flaring
Talk to a specialist
Hotel, illustrative imageIllustrative image

Hotels, resorts and hospitals

Electricity, hot water for bathing and pools, and air conditioning from a single source, quiet and oil-free.

  • Hot water from the exhaust
  • Low noise and vibration
  • Backup power for critical loads
Talk to a specialist
Telecom towers

Telecom

Continuous power for telecom sites and exchanges, with maintenance every 8.000 h and remote monitoring.

  • Remote operation via 4G
  • Long maintenance intervals
  • LPG or natural gas

Manufacturer specifications at ISO conditions, PCI (LHV). Performance varies with operating conditions.

Talk to a specialist
Agribusiness farm

Agribusiness

Biogas from swine, poultry and cattle manure turned into power and heat for the farm.

  • Waste becomes fuel
  • Heat for warming barns
  • Sale or offsetting of energy
Talk to a specialist